Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T21PI00014
Parcel: Unknown

Address:
3131 S PORTIA AV

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T21PI00014
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/06/2021 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change 1. Provide a STOP sign for the EB direction where it ties into the newly created 4-leg intersection at Bonanza Ave/Gray Hawk Dr.

Greg Orsini, P.E.
Gregory.Orsini@tucsonaz.gov
520-837-6617
12/06/2021 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/06/2021 ERNIE ENCINAS DOT_ELEC REVIEW Approved
12/06/2021 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/06/2021 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/06/2021 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/06/2021 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/06/2021 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/20/2021 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/20/2021 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Completed Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/20/2021 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter Which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines.
12/28/2021 GARY WITTWER DOT LANDSCAPE REVIEW Reqs Change DTM Landscape Comments:

1. Please include the following notes for Private Irrigation in the ROW on the plans. These are not on the DP or other associated plans that I can find.

2. City of Tucson, Department of Transportation and Mobility
Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way

IRRIGATION NOTES:

1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways.

2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way.

3. The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member.

4. Minimize the number of roadway crossings.

5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting.

6. Irrigation lines shall be placed in ductile iron sleeves.

7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by DOT&M.

8. HDPE continuous line (no joints under the pavement)

9. Irrigation lines shall have a minimum of thirty (30) inches of cover.

10. Detectable marking tape shall be installed.

11. Curb shall be marked/stamped with “IS” (Irrigation System) and/or placard at back of curb.

Reviewer:

David Marhefka
da’-vid mär-hef’-ka
Landscape Architect
City of Tucson
Department of Transportation and Mobility
(o) 520-837-6618
(m) 520-403-5074
12/28/2021 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
12/28/2021 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change December 28, 2021

SUBJECT: Offsite Improvement Plan for Casitas Del Cerrito

PROJECT REVIEWER: Richard Leigh, DTM Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments.


1. Address redline comments on plan markups emailed.
2. Submit the approved development plan and drainage report for the development.

If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov.
12/28/2021 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed
12/28/2021 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved