Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T21PI00013
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2021 GARY WITTWER DOT LANDSCAPE REVIEW Approved
11/15/2021 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
11/15/2021 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change Here are my comments on the Bella Tierra Phase 3 plans:

1- Sheet 9, on Irvington Rd, why is 6' sidewalk proposed to be constructed out of AC instead of concrete? Concrete likely to have longer service life

2- Sheet 12, on Wingate Blvd, with 47 feet of pavement, recommend that typical section be revised to include 7 foot bike lane (5 feet + 2 foot buffer space), 11 foot travel lane, 11 foot TWLTL, 11 foot travel lane, and 7 foot bike lane (5 feet + 2 foot buffer space). WS6 stripe is travel lane edge stripe, WS4 is 2 feet offset for buffer space, leaving 5 foot bike area

3- Sheet 12, near Sta 81 and 82, please remove left turn arrows from plan. City does not typically place arrows or legends in single left turn lanes for maintenance reasons

4- Sheet 12, also for left turn lane, western stripe for SB left turn lane should be WS8, not YDS4

5- Sheet 12, do we need Bike Lane Ends signage for SB direction?

Thank you,
Greg Orsini, P.E.
Gregory.Orsini@tucsonaz.gov
11/15/2021 ERNIE ENCINAS DOT_ELEC REVIEW Approved
11/15/2021 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
11/15/2021 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
11/15/2021 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review
11/18/2021 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change Refer to redline drawings for comments.
11/18/2021 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
11/18/2021 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed