Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T21PI00001
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/17/2021 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Needs Review | |
| 02/17/2021 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | DTM Traffic Engineering: 1. Per the Pima County/City of Tucson Signing and Pavement Marking Manual, 2020, Sheet 8.3 (Minor Street) and Appendix A, Page 3, the minimum right turn storage length is 150' and the minimum taper is 15:1 (180'). I don't know if this applies to minor driveway but would assume so 2. Two streetlights will be relocated 12-feet away from the through lanes. Is there any concern regarding photometrics? Blake Olofson, P.E. Traffic Engineering Safety Manager City of Tucson Tucson AZ 85701 (520) 837-6667 Office (520) 373-3798 Mobile Blake.Olofson@tucsonaz.gov |
| 02/17/2021 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | Please submit utility notification confirmation for the utility companies listed on the PIA utility notification list. The list can be found at: https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines |
| 02/17/2021 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 02/17/2021 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Reqs Change | DTM Electric Shop: Add the following General note: TRAFFIC MAINTENANCE, CITY OF TUCSON DEPARTMENT OF TRANSPORTATION AND MOBILITY THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING AND/OR RELOCATING NEW AND EXISTING ELECTRICAL JUNCTION BOXES AND STREET LIGHTS. ALL ELECTRICAL INSTALLATIONS SHALL MEET CITY OF TUCSON STANDARD SPECIFICATIONS AND DETAILS. CONTRACTOR SHALL CONTACT TRAFFIC MAINTENANCE FOR COORDINATION OF THIS WORK PRIOR TO CONSTRUCTION AT 520-837-6801. Gabriel Rascon Traffic Maintenance Superintendent Department of Transportation and Mobility Mobile: (520) 400-7656 Gabriel.Rascon@tucsonaz.gov _______________________________________ Address comments redlined on drawing: scan_abracam1_2021-01-22-10-55-31.PDF Armando 'Brac' Bracamonte Electrician Supervisor - Traffic Signals & 811 Department of Transportation 520-837-6802 |
| 02/17/2021 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | February 17, 2021 SUBJECT: Offsite Improvement Plan for TuSimple Expansion PROJECT REVIEWER: Richard Leigh, DTM Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments. 1. Add the plan number "U-2021-001" in the title block of each sheet. 2. Add PIA activity number "T21PI00001" on coversheet. 3. Sheet 1: Paving Note 3 to indicate that the asphaltic concrete shall conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019. 4. Sheet 2: Relocate the curb access ramp on the east side of the east driveway to be in line with the curb access ramp across it. Refer to COT TSM Section 10-01.3.3.E. 5. Sheet 2: Revise keynote 11 to indicate ramp type. 6. Sheet 2: The proposed slopes within the right turn lane does not meet minimum slope requirements. Refer to COT TSM 10-01.1.4.5 7. Provide a geotechnical analysis supporting the proposed pavement structural section. The existing pavement structural section has a 6" concrete treated base. See as-built plan I-86-002. 8. Refer to redline drawings for additional comments and comment details. If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov. |
| 02/17/2021 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | Please submit utility notification confirmation for the utility companies listed on the PIA utility notification list. The list can be found at: https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
| 02/17/2021 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review |