Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW - RESIDENTIAL
Permit Number - T21CM09890
Review Name: 3RD PARTY REVIEW - RESIDENTIAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 01/20/2022 | DBENOIT1 | NPPO | REVIEW | Passed | |
| 01/20/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM09890 2435 N Santa Rita Ave – Residence 2 as shown on the plan – R-2 New 980 SSFR (1st Review) TRANSMITTAL DATE: January 20, 2022 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. Provide a setback dimension from the post support the porch, shown along the north side of the house, to the north property line. 2. Provide a setback dimension from the southwest corner of the proposed house to the property line directly south. Once the above dimensions are provided and as it does not appear that perimeter yard setbacks are met for comments 1 & 2 additional DDO comments maybe forth coming. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 3. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. That side provide height dimensions from design grade to the top of parapet. As dimensions to design grade were not provided Zoning is adding 6” to the provided dimensions for setback purposes. 4. Based on a wall height of 11’-6” the required perimeter yard setback from the proposed SFR to the north property line is 7’-8”, proposed setback is 7’-4” a Design Development Option will need to be submitted and approved for the reduced setback. 5. Based on a wall height of 11’-6” the required perimeter yard setback from the proposed SFR to the south property line is 7’-8”, proposed setback is 7’-4” a Design Development Option will need to be submitted and approved for the reduced setback. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. Until comments 1 & 2 have been addressed and a 2nd Zoning review is commented do not apply for the required DDO. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 01/28/2022 | WILDAN | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Needs Review | |
| 01/28/2022 | WILDAN | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/26/2022 | VVERA1 | OUT TO CUSTOMER | Completed |