Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T21CM09887
Parcel: 11004345H

Address:
3215 N SWAN RD

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM09887
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/03/2022 SBLOOD1 ENGINEERING REVIEW Passed
01/05/2022 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
01/12/2022 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
01/12/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The developed length of the hot water supply piping from the water heater to the new sinks appears to be greater than fifty feet; provide a method for maintaining the temperature of the hot water supply system. Reference: Section 607.2, IPC 2018 and C404.5, IECC 2018.
2. Provide cleanouts for all horizontal drains (i.e. a 2" cleanout at each hand sink). Reference: Section 708.1.1, IPC 2018.
01/12/2022 ROBERT SHERRY WATER REVIEW Completed
01/14/2022 JVINCEN1 FIRE REVIEW Approved
01/20/2022 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
01/21/2022 STEVE SHIELDS ZONING REVIEW Approved
01/21/2022 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed