04/06/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM09886

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved


BUILDING REVIEW COMMENTS:
Denied
1b) Ceiling R-value: R-38. Unresolved - This prescriptive value (R-38) must be installed at the ceiling level or provide a REScheck energy compliance report with HVAC trade-offs that may allow for a reduction of this ceiling R-value.
Answer to response letter: The RHVAC report does not regulate the R-value, it is a heat loss/heat gain report designed to figure out what size of equipment is needed to heat and/or cooling the building, efficiently.


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
Approved