Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM09886
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2022 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | CDRC Transmittal FROM: Loran Shamis PDSD Zoning Review Section PROJECT: T21CM09886 Single Family Residential attached addition (1st Review) 2401 W Called Placida TRANSMITTAL DATE: January 11, 2022 DUE DATE: January 13, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The site is zoned R-1 , and the proposed use is Single family residential (11.3.7.A.4) which is a permitted use in your zone, subject to use specific standards 4.9.7.B.5-.9 (Table 4.8-2). 01. COMMENT: Provide a residential plot plan that meets the requirements found at https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This plan will: a. Be drawn at an engineering scale, i.e. 1"=10' b. Provide a lot coverage calculation c. Show the location of all utilities d. Indicate the zoning of the surround properties e. Provide a legal description 02. COMMENT: It is unclear if the proposed attached addition is meeting the minimum setback requirements for your zone from your western property line. The minimum setback requirements for residential uses in the R-1 zone adjacent to residential zones is the greater of 6' or 2/3 the height of the adjacent wall measured from the exterior of the structure to the property line. 03. COMMENT: The zoning reviewer acknowledges the addition is labeled as an "office" however it meets the criteria for a fifth bedroom. Per applicable use specific standard 4.9.7.B.7 for all single-family dwellings in the R-1 zone with five or more bedrooms all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be locating in a vehicular use area in any front street perimeter yard. Demonstrate compliance on the site plan. Secondary access using the alley is permittable to meet this requirement. 04. COMMENT: Include all setbacks for both proposed and existing structures. 05. COMMENT: Include the lot coverage calculation. The lot coverage is the percent of the lot area that is covered by buildings, storage areas, and vehicular use areas. See UDC 6.4.3 for applicability standards. For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 01/25/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 02/08/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM09886 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1) Provide rafter detail 2) Energy Code: a) Provide detail for walls, windows, & ceiling BUILDING REVIEW COMMENTS: Denied 1) Provide rafter detail 2) Energy Code: a) Provide detail for walls, windows, & ceiling MECHANICAL REVIEW COMMENTS: Denied 1) Provide rafter detail 2) Energy Code: a) Provide detail for walls, windows, & ceiling ELECTRICAL REVIEW COMMENTS Denied 1) Provide rafter detail 2) Energy Code: a) Provide detail for walls, windows, & ceiling PLUMBING REVIEW COMMENTS: Denied 1) Provide rafter detail 2) Energy Code: a) Provide detail for walls, windows, & ceiling |