Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM09884
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM09884 1019 W Huron St. – R-2 Fire Damage Repair & Enclose Existing Porch to Room (1st Review) TRANSMITTAL: January 11, 2022 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 4.9.7.B.5 - .9. 1. Based on aerial photos there has been an addition to the southwest corner of the structure. Zoning was not able to find permits for this addition. Either provide the approved permit documents with your next submittal or include this with this permit. 2. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Parapet walls are measured to the top of parapet. As dimensions from design grade to the highest point of the exterior walls were not provided perimeter yard setback requirements cannot be verified. It appears that the addition to the southwest corner of the structure doe not meet perimeter yard setbacks to the south and west property line. A Design Development Option (DDO) may be required to reduce the required setbacks, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. 3. The lot coverage calculation is not correct. Per UDC Article 6.4.3.B.3.b vehicular use areas , measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage. 4. The pdf drawings files shall be submitted as a single multi-page pdf file. If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov. |
| 01/25/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 02/08/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM09884 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1) Update codes: a) IRC: 2018 b) Electrical: 2017 NFPA 70 2) Total conditioned space does not match floor plan. 3) Provide job scope for fire restoration: a) Plumbing b) Mechanical BUILDING REVIEW COMMENTS: Denied 1) Update codes: a) IRC: 2018 b) Electrical: 2017 NFPA 70 2) Total conditioned space does not match floor plan. 3) Provide job scope for fire restoration: a) Plumbing b) Mechanical MECHANICAL REVIEW COMMENTS: Denied 1) Update codes: a) IRC: 2018 b) Electrical: 2017 NFPA 70 2) Total conditioned space does not match floor plan. 3) Provide job scope for fire restoration: a) Plumbing b) Mechanical ELECTRICAL REVIEW COMMENTS Denied 1) Update codes: a) IRC: 2018 b) Electrical: 2017 NFPA 70 2) Total conditioned space does not match floor plan. 3) Provide job scope for fire restoration: a) Plumbing b) Mechanical PLUMBING REVIEW COMMENTS: Denied 1) Update codes: a) IRC: 2018 b) Electrical: 2017 NFPA 70 2) Total conditioned space does not match floor plan. 3) Provide job scope for fire restoration: a) Plumbing b) Mechanical |