Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM09867
Parcel: 11616287A

Address:
845 N MAIN AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM09867
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The freeze resistant option shown in detail 7 provides a cross-connection to wastewater and cannot be used to deliver potable water. Reference: Section 608.8, IPC 2018. [Initial comment: Show how the proposed handwashing/drinking fountain will be protected from freezing (e.g. freeze-resistant model from manufacturer). Reference: Section 305.4, IPC 2018.]