Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM09778
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/10/2022 | JPEELDA1 | FIRE | REVIEW | Approved | |
01/12/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
01/12/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM09778 1448 E 1st St – R-3 Façade Modifications (1st Review) TRANSMITTAL DATE: January 12, 2022 This site is located in the R-3 zone (UDC 4.7.12). A group dwelling is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6. 1. As you are proposing façade modifications which appear to change the height of the exterior walls that effect the requirements for street perimeter yard setbacks per UDC Article 3.3.3.G.2.c a new site plan, Development Package (DP), is required to be submitted and approved prior to approval of this building permit. The DP shall meet the requirements of the checklist for Minor Changes to Commercial/Industrial Sites found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf. If you have any questions about this transmittal, please contact Elisa Hamblin at ElisaHamblin@tucsonaz.gov. |
01/12/2022 | SSHIELD1 | ENGINEERING | REVIEW | Reqs Change | See Zoning Comments |
01/12/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
01/18/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM09778 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved 1. No Geotechnical Report is provided and Presumptive Allowable Bearing Capacity of 1500 psf. is used in the design. The Engineer of Record to verify Soil Conditions on Site before Construction. BUILDING REVIEW COMMENTS: Conditionally Approved 1. Provide an existing occupant load. MECHANICAL REVIEW COMMENTS: Conditionally Approved 1. No mechanical plans submitted no new mechanical work being done 2. Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied 1). Add Scupper & downspout sizing calculations to Plan pg. A1 or A3, calculations need to derive from IPC 1106.1, 1106.3, 1106.5, 1108 |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/18/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |