Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM09666
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 01/11/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM09666 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Approval Pending 1. Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Denied E0.02 ELECTRICAL POWER DISTRIBUTION DIAGRAMS AND SCHEDULES: Need to perform and show short circuit calculations on Power Distribution Diagram for new Panels A and B to prove/show that selected 22 KAIC rating is adequate. E2.01 ELECTRICAL LIGHTING: Should provide an exit sign for Staff Break Rm. E4.01 ELECTRICAL SYSTEMS: Cannot locate Circuit or any other information for EUH-1. Suggest to add note to refer to E0.2 Mechanical Schedule for connection/conductor information PLUMBING REVIEW COMMENTS: Denied 1). WB-1 & WB-3 on plan pg, P0.01 need backflow devices that comply with IPC 608.17.1 2). Add 1" hot water pipe insulation to plan page P0.01 -IPC 607.2.1 607.5 3). add seismic supports to WH detail on plan page P7.01 -IPC 502.4 |
| 01/12/2022 | SSHIELD1 | ENGINEERING | REVIEW | Needs Review | |
| 01/12/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 01/12/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM09666 5100 E Broadway Blvd – PAD_1 TI Medical Office (1st Review) TRANSMITTAL: January 12, 2022 This site is located in the PAD-1. Medical Service, Out Patient is an allowed use in the PAD. 1. As exterior work is proposed design review by the Williams Center Owners Review is required, PAD-1 Section XI.C. Provide a copy of the approved review letter with your next submittal. 2. As demolition of existing railings, concrete patio and stairs along the north side of the building is proposed a development package may be required. The extent of the work Is not clear and accessible access from the street & accessible parking spaces must be maintained. Clarify exactly what is happening along north side of the building. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 02/10/2022 | JVINCEN1 | FIRE | REVIEW | Approved |