Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM09633
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 01/06/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | The mechanical design requires 45 CFM of continuous ventilation for the dwelling unit. Show how the ventilation is being provided. Reference: Sections 401.2 and 401.3, IMC 2018. |
| 01/06/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1. The disconnect switch and equipment shown in bedroom #2 is assigned to branch circuit #A:30. The new panel ‘A’ is limited to 24 circuits. Please clarify. 2. Provide for a lighting outlet in the bathroom #2, utility rooms, washroom. NEC 210.70 3. The description of the scope of work on the title sheet included replacing the luminaires (light fixtures). Provide compliance with the 2018 IECC residential section. Also the replaced exterior luminaires lamp color temperature output must not exceed 3500k. Section 402.1 OLC. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, 2012 Tucson/Pima County outdoor Lighting Code, (OLC). |
| 01/06/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 12/21/2021 | JGARCIA1 | ENGINEERING | REVIEW | Passed | |
| 12/21/2021 | JGARCIA1 | ZONING | REVIEW | Passed | |
| 12/21/2021 | JGARCIA1 | WATER | REVIEW | Passed | |
| 12/21/2021 | JGARCIA1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 12/29/2021 | JVINCEN1 | FIRE | REVIEW | Approved |