Permit Number: T21CM09609
Parcel: 128111110

Address:
232 S NEMA PL

Review Status: Completed

Review Details: 3RD PARTY REVIEW - REVISION/OTHER

Permit Number - T21CM09609
Review Name: 3RD PARTY REVIEW - REVISION/OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/07/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM09609
232 S Nema Pl – R-1
Second dwelling Unit (2nd Review)

TRANSMITTAL DATE: March 07, 2022

This site is located in the R-1 zone (UDC 4.7.8). A single family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. This comment was not addressed. The 3 vehicle parking spaces shown in the front yard do not meet the requirements as they are located in the front yard. As you are proposing a 2nd dwelling unit with 2 bedrooms on this site the requirements of Unified Development Code Article 4.9.7.B.7 For any new single-family dwelling in the R-1 zone with five bedrooms , three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms , and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard . A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used, apply. Demonstrate how these requirements are met on the plan.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov