Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM09460
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 01/04/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 01/04/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 01/05/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 01/05/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 01/05/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 01/10/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/16/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A2.0 (Floor Plan); Sheet A4.0 (Door Schedule): Door 108A (entering the Safe Room 108) indicates a hardware set number 2, which has a storage lock on the door. Two exits are not required for this tenant space (10 occupants). However, your Code Review Checklist (Sheet A1.0) indicates "2 exits provided". The IBC Section 1016.2(3) indicates an exit access can not pass through a room that can be locked. Please verify and remove the door lock or revise the Code Review Checklist. 2. Sheet A2.0; Floor Plan: It appears even if Door 108A has a lock, the dead end corridor length meets the requirements of the IBC Section 1020.4(2), and meets the common path of egress travel distance listed in the IBC Table 1006.2.1. If the door will be lockable, please indicate the dead end corridor length and the common path of egress travel distance on Sheet A2.0. 3. General: Please provide written responses to all review comments. |
| 12/30/2021 | JVINCEN1 | FIRE | REVIEW | Approved |