Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T21CM09267
Parcel: 12404102B

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM09267
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/21/2022 SBLOOD1 ENGINEERING REVIEW Passed
12/07/2021 JPEELDA1 FIRE REVIEW Reqs Change IFC 2018, Section 1010.1.10 Panic and Exit Hardware. Swinging doors serving a Group H occupancy and swing doors serving rooms or spaces with an occupant load of 50 or more in Group A or E occupancy shall bot be provided with a latch or lock other than panic hardware or fire exit hardware. Please revise the exterior gates.

Questions:
Jennifer Peel-Davis
520-837-7033
Jennifer.Peel-Davis@Tucsonaz.gov
12/08/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet G1.0; Code Analysis: This analysis must combine the two suites into one space. Remove the reference in the General Building Summary to the separate suites. There should be one building SF and one building Occupant Load.
2. Sheet G1.0; Code Analysis (General Building Summary): Please revise the Allowable Building Area for the space per IBC Table 506.2 for an A-2 sprinklered building.
3. Sheet G1.0; Code Analysis: The Occupant Load must include the occupants from the added patio. Please provide.
4. Sheet G1.0; Code Analysis: Please provide the calculations for the required plumbing fixtures on this sheet per the IBC Table 2902.1.
5. Sheet A1.0; Floor Plan: Please indicate the seating at the patio addition. Provide accessible seating and tables as required by the IBC Section 1109.11.
6. Sheet A1.0; Floor Plan: The plan indicates new exit lights and a prefabricated ramp to exit from an existing office. Per the IBC Section 1016.2(3), an exit access shall not pass through a room that can be locked to prevent egress. Please verify.
7. Sheet A1.0; Floor Plan: Per the IBC Section 1016.2(5), the existing exit door on the east wall may not be considered an exit door due to the requirement that egress to an exit shall not pass through kitchens or storage rooms. Please verify.
8. Sheet A1.0; Floor Plan: Please provide details for the new header and support jambs for the new opening in the interior wall.
9. General: Please provide written responses to all review comments.
12/16/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
12/16/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
12/16/2021 ROBERT SHERRY WATER REVIEW Completed
12/21/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
12/27/2021 STEVE SHIELDS ZONING REVIEW Approved
12/27/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed