Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM09267
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/21/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 12/07/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | IFC 2018, Section 1010.1.10 Panic and Exit Hardware. Swinging doors serving a Group H occupancy and swing doors serving rooms or spaces with an occupant load of 50 or more in Group A or E occupancy shall bot be provided with a latch or lock other than panic hardware or fire exit hardware. Please revise the exterior gates. Questions: Jennifer Peel-Davis 520-837-7033 Jennifer.Peel-Davis@Tucsonaz.gov |
| 12/08/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet G1.0; Code Analysis: This analysis must combine the two suites into one space. Remove the reference in the General Building Summary to the separate suites. There should be one building SF and one building Occupant Load. 2. Sheet G1.0; Code Analysis (General Building Summary): Please revise the Allowable Building Area for the space per IBC Table 506.2 for an A-2 sprinklered building. 3. Sheet G1.0; Code Analysis: The Occupant Load must include the occupants from the added patio. Please provide. 4. Sheet G1.0; Code Analysis: Please provide the calculations for the required plumbing fixtures on this sheet per the IBC Table 2902.1. 5. Sheet A1.0; Floor Plan: Please indicate the seating at the patio addition. Provide accessible seating and tables as required by the IBC Section 1109.11. 6. Sheet A1.0; Floor Plan: The plan indicates new exit lights and a prefabricated ramp to exit from an existing office. Per the IBC Section 1016.2(3), an exit access shall not pass through a room that can be locked to prevent egress. Please verify. 7. Sheet A1.0; Floor Plan: Per the IBC Section 1016.2(5), the existing exit door on the east wall may not be considered an exit door due to the requirement that egress to an exit shall not pass through kitchens or storage rooms. Please verify. 8. Sheet A1.0; Floor Plan: Please provide details for the new header and support jambs for the new opening in the interior wall. 9. General: Please provide written responses to all review comments. |
| 12/16/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 12/16/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 12/16/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 12/21/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/27/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 12/27/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |