Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM09221
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 12/08/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 12/09/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM09221 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Provide the square footage calculations for all buildings in the scope of work. 2. On almost every page of the drawing set, the file seems corrupted and there are lines running through the floor plan. 3. On almost every page of the drawing set, lines are missing from the drawing. Please correct drawing and provide a completed drawing. 4. Please provide a prescriptive path or provide COMcheck calculations for the new lighting. All mandatory requirements must be identified on the plans for compliance. Provide a fixture schedule. 5. Provide any updated panel schedule as needed. MECHANICAL REVIEW COMMENTS: Denied 1. Provide mechanical plans (IMC2018,106.3.1) ELECTRICAL REVIEW COMMENTS Denied No electrical to review PLUMBING REVIEW COMMENTS: Denied 1). Sheet index on plan Pg. 001 list plan sections 400, 600, & 700 label not used or include the pages. -IPC A106.3.1 |
| 12/22/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM09221 7060 S Tucson Blvd – P-I/I-1 TI Travelers Accommodation, Lodging w/Minor Façade Changes and ADA Upgrades (1st Review) TRANSMITTAL: December 22, 2021 This site is located in the P-I/I-1 zone (UDC 4.7.28 & 4.7.29). Travelers Accommodation, Lodging is an allowed use in the P-I/I-1 zone (UDC Table 4.8-5), subject to Use Specific Standards 4.9.13.Q 1. Provide a general note on drawing 100 stating “ALL MODIFICATIONS TO EXISTING AND PROPOSED ACCESSIBLE ROUTES, RAMPS AND VEHCILE PARKING SPACES TO COMPLY WITH 2018 IBC CHAPTER 11 AND THE ICC A117.1-2009. 2. Drawing 100 Drawing Note 1 lists Drawings 204S & 214S, Zoning was not able to find these drawings and they are not referenced within the drawing index. Also, it does not appear that the drawing index matches what was submitted. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 12/22/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 12/22/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/04/2022 | VVERA1 | OUT TO CUSTOMER | Completed |