Permit Number: T21CM09065
Parcel: 123153010

Address:
1214 E ELM ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM09065
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/26/2021 SBLOOD1 ENGINEERING REVIEW Passed
12/02/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM09065
1214 E Elm St – R-2
2 SFR’s

TRANSMITTAL: December 2, 2021
This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. As drawn this plan is considered an addition of a 2nd dwelling unit. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-2 ZONE, Residential Density of 15 units per acre the minimum lot size required for 2 dwelling units is 5,808 Sq. Ft. The simple fix would be to remove the full size refrigerator and show it as an under counter refrigerator, the addition would then be considered a sleeping quarters and the non-conforming lot size, R-2 minimum lot size for a single family dwelling is 5,000 Sq. Ft., see table above, would not be an issue.

2. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the requirement for a Residential Plot Plan found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

3. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-2 Zone, residential use to a residential zone the required perimeter yard setback is 6’-0” or 2/3 the height of the exterior wall, greater of the two. As a correct wall height for the south wall was not provided Zoning used a measurement taken with our Bluebeam review software it appears that the wall height along the south property line is less than 9’-0” requiring a perimeter yard setback of 6’-0”, proposed perimeter yard setback is 4’-0”. A Design Development Option (DDO) will need to be submitted and approved for the reduced setbacks. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

4. The “FRONT” setback listed on the plan is not correct and should be 20’ or 1-1/2 times the height of the exterior wall, greater of the two, see UDC Article 6.4.5.C.1.a.

5. As the ADU regulations have not been adopted by Mayor & Council remove all reference to the ADU from the plan.

If you have any questions about this transmittal, please contact Elisa Hamblin at ElisaHamblin@tucsonaz.gov.
12/16/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM09065 Addition to Existing Dwelling

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical of a dwelling addition rather than as a new dwelling. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Place the reference on the plans.

SITE PLAN:

Provide a site plan showing all buildings, R106.1.1. Show the water line size to the building as a 1” pipe is required for the total water demand.

SECTIONS - DETAILS:

Update detail #7/A3.0 showing the wall on a bearing foundation.

MECHANICAL PLANS:

Provide equipment details showing code compliant components, locations and sizes. Provide a Manual J report identifying cooling demand.

ELECTRICAL PLANS:

Provide proposed wiring details showing code compliant device locations and circuit sizes. Show circuit number and size with receptacles at all walls and lighting control at each doorway both interior and exterior. Receptacle, lighting and smoke detector circuits require arc-fault protection.

Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16.

OUTDOOR LIGHTING CODE

Provide any alterations with details showing compliant fixtures. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations or show proposed fixtures as Full Cut Off (night sky friendly).

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review