Permit Number: T21CM08992
Parcel: 137276400

Address:
2075 W DREXEL RD

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM08992
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/18/2021 SBLOOD1 ENGINEERING REVIEW Approved
11/29/2021 AWARNER1 NPPO REVIEW Passed
12/01/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM08992
1248 N Norton Av – RX-1
Detached Storage Shed (1st Review)

TRANSMITTAL DATE: December 1, 2021

This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3). See Use-Specific Standards 4.9.7.B.6, .8, & .9.

1. As the guest house permit, T21CM06973, has not been approved, remove all reference to the guest house from the storage shed plans.

2. Per Unified Development Code (UDC) TABLE 6.3-1.A: DIMENSIONAL STANDARDS FOR THE RH, SR, SH, RX-1, & RX-2 ZONES, RX-1 Zone the required perimeter yard setback from the proposed storage shed to the south property line is 20’-0”, proposed perimeter yard setback is 15’-0”. At a minimum a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the only of the property to the south:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

3. Provide the gross floor area of the Est. House on the plan. Per UDC Article 6.6.3.d the accessory structure, proposed shed cannot exceed 50% of the gfa of the principal structure.

If you have any questions about this transmittal, please contact Elisa Hamblin at ElisaHamblin@tucsonaz.gov.
12/14/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed