Permit Number: T21CM08932
Parcel: 136202550

Address:
2635 S JAGUAR RD

Review Status: Completed

Review Details: OTHER

Permit Number - T21CM08932
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/08/2021 PCAMARE1 OIP REVIEW Reqs Change FROM: Paul Camarena
PDSD Residential Review Section

PROJECT: T21CM08932
Roof top Solar Panels (1st Review)
2635 S JAGUAR RD

TRANSMITTAL DATE: December 8, 2021



COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Residential Review Section comments were addressed.


COMMENT: Residential has reviewed the plan and cannot approve at this time. Please address the following comments


COMMENT: After reviewing the plot plan and aerials it has come to my attention that roof has a slope please provide the slope of the roof. If the slope of the building is greater than 2:12 then compliance to 2018 International Fire Code 1204.2.1.1. must be shown on the plans. Show a 36” wide access pathway from the eave to the ridge on both sides of the building.


COMMENT: Residential will review the application on the next submittal


If you have any questions about this transmittal, Contact Paul Camarena any time during the week by email Paul.camarena@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans

Final Status

Task End Date Reviewer's Name Type of Review Description
12/08/2021 NGARCIA3 OUT TO CUSTOMER Completed