Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM08927
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/17/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1 The PV tap box (interconnection) is not shown in the electrical equipment elevation drawing E604.00. Verify the distance between the interconnection taps and the PV DG disconnect switch. If more than 10’ NEC art 690.15 will apply. 2. Verify that the DG disconnect switch is rated suitable for use as service equipment NEC 690.13C. Ref; 2018 IBC sec 107.2.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. |
| 03/04/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM08927 333 W Ajo Wy – C-2 Shade Structure w/Solar (3rd Review) TRANSMITTAL: March 4, 2022 This site is located in the C-2 zone (UDC 4.7.21). 1. This comment was not addressed. Per UDC Article 3.3.3.G.2.c when structure additions are proposed a development package is required. A development package (DP) meeting the requirements of the checklist for Minor Changes to a Commercial/Industrial Site found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf, shall be submitted and approved prior to approving this building plan. A The DP is a separate submittal from the building plan and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. . |
| 03/18/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | See zoning comments for need of a DP Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |