Permit Number: T21CM08914
Parcel: 136343940

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM08914
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2021 SBLOOD1 ENGINEERING REVIEW Passed
11/29/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: PDSD Zoning Review

PROJECT:
T21CM08914
7311 E Lakeside Dr - R-1
Detached Shed (1st Review)

TRANSMITTAL: November 29, 2021

This site is located in the R-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Provide a residential plot plan the meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. The provide plot plan does not show the entire parcel and is required to show the entire parcel. The following shall be included on the plot plan:
a. Lot coverage calculation meeting the requirements show on the above requirements and Unified Development Code (UDC) Article 6.4.3.
b. Owners name,
c. Zoning of the parcel and all adjacent parcels.

2. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (UDC Table 6.3-2.A). That said based on what appears to be 13’-4” for the north elevation of the shed the required perimeter yard setback to the north property line is 8’-11”. Either locate the shed so it meets the setback requirements or provided a neighbor’s setback waiver for the property north of the alley. Zoning acknowledges the provided setback waiver for the property to the west but the statement shown on the example submitted is required to be on the site plan (plot plan), this is required for both setbacks.

3. The Tuff Shed drawings provided at not readable.


If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
12/13/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide construction plans with an Arizona Engineer stamp for the manufactured design. Plans show foundation fastener requirements.