Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM08674
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2021 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | FROM: Loran Shamis PDSD Zoning Review Section PROJECT:T21CM08674 1103 E Waverly NR-1, Jefferson Park Neighborhood TRANSMITTAL: November 17, 2021 COMMENTS: the following comments are relative to an application for NPZ Review (UDC 5.10.3). This site is in the NR-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B-.9. Prior to zoning approval an NPZ review and approval is required. For more information Contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov or (520) 837-6933. Apply here for NPZ review - https://www.tucsonaz.gov/files/integrated-planning/Special_Districts_Application_Revised_9-10-21_fillable.pdf |
| 11/17/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 12/02/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM08674 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Show the location and size of buildings, utility meters and electric and water line from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. STRUCTURAL PLANS: 1. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. Show truss calculations with cross-reference to the plans, R802.10.2. Notate the size and weight of attic or roof mounted equipment on the Roof Framing Plan required for the truss design, M1401. PLUMBING PLANS: 1. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |