Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T21CM08672
Parcel: 113077450

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM08672
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM08672
1620 E Hedrick Dr – R-2
New Duplex (1st Review)

TRANSMITTAL DATE: November 19, 2021

This site is located in the R-2 zone (UDC 4.7.9). A Duplex is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. Based on the approved Development Package DP20-0163 and the vehicle parking provided, four (4) spaces, this site is limited to a duplex with a 3 bedroom unit and a 2 bedroom unit only. The submitted plan is using model plan T21-M0024 which is a duplex with four (4) bedrooms in each unit which requires five (5) vehicle parking spaces. A site that requires five (5) vehicle parking spaces is required to meet commercial landscape and pedestrian circulation requirements. Either the DP will need to be revised to show five (5) vehicle parking spaces and all required landscape buffers, pedestrian circulation, etc. or the model plan revised to show no more than five (5) bedrooms total or a different model plan that only has five (5) bedrooms total.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
11/24/2021 SSHIELD1 ENGINEERING REVIEW Reqs Change See Zoning comments
12/02/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed