Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM08602
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/03/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 11/18/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM08602 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Provide an existing/demolition plan. 2. The construction type is listed as type III construction. Indicate whether it is type IIIA or IIIB construction and coordinate and applicable requirements. 3. The occupant load for the fulfillment area is calculated incorrectly. This is similar to a business area and should be calculated at 150 per sq. ft. The MED VIP room is not included in the calculation. Provide a table of each space along with the calculation for each space. MECHANICAL REVIEW COMMENTS: Denied 1. Provide an approved mechanical ventilation system with CO and NO2 detectors in the enclosed parking garage (intake room) (IMC2018,404) ELECTRICAL REVIEW COMMENTS Denied E1.0: No electrical issues E2.0: No electrical issues. FYI: Provided IEC 2018 energy calculations which meet comcheck requirement for this reviewer. Other reviewers may require output from comcheck software (free to download and use) on future submittals. E2.1: No electrical issues E3.0: No electrical issues E4.0: Fire alarm plan needs to show pull stations at all normal and emergency egress points. E5.0: Tucson requires fault current calculations to new panels. E5.0: Rooftop units HP2, 3, 4, & 5 are under reported on panel schedule L1 vs AMPS shown on E3.0 Mechanical Equipment Schedule. Does not affect design. PLUMBING REVIEW COMMENTS: Denied 1). Condensate discharge to the sanitary needs to be indirect. update general note #6 on Plan pg. P1.0. -IPC 802.1.5 2). Can't replace the High/Low drinking fountain with a bottle filler only. A High/low drinking fountain will need to be reinstalled with or without a bottle filler attachment. Update P6 on fixture schedule on plan pg. P2.0 & Keynote #6 on P1.0 -IPC 410.3 410.4 |
| 11/22/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM08602 7139 E 22nd St – C-2 Marijuana Dispensary w/Drive-through TRANSMITTAL: November 22, 2021 This site is located in the C-2 zone (UDC 4.7.21). Marijuana Dispensary use is allowed in the zone (Table 4.8-4) subject to Use Specific Standard 4.9.9.E.1. 1. The proposed dispensary exceeds the allowed 10,000 square footage per UDC Article 4.9.9.E.1.a. 2. Provide a calculation that clearly demonstrates that the requirement of UDC Article 4.9.9.E.1.d is met. 3. Clearly demonstrate on the plans how the requirements of UDC Article 4.9.9.E.1.I are met. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 11/22/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 11/22/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 11/22/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/23/2021 | NGARCIA3 | OUT TO CUSTOMER | Completed |