Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM08523
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 11/12/2021 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | CDRC Transmittal FROM: Loran Shamis PDSD Zoning Review Section PROJECT: T21CM08523 Manufactured home addition - enclose carport to storage and convert storage to carport (1st Review) 5986 E Greyhawk Ranch Rd TRANSMITTAL DATE: November 12, 2021 DUE DATE: November 17, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The subject property is zoned SH and a manufactured home is permitted in this zone. 01.COMMENT: Provide a residential plot plan that meets the requirements found at https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf a.Lot coverage calculation b.Property owner information c.All existing and proposed structures, laeled with dimensions d.A brief legal description e.Zone of adjacent property 02.COMMENT: There are existing structures on the property that are not included in your site plan. Include all structures and provide all the necessary information for review. 03.COMMENT: It appears the structure furthest to the south is not meeting the minimum required setback for the property to the west - the minimum setback requirement is 20'. If the structure is not meeting the minimum setback requirement a neighbor waiver can be obtained to reduce the set ack requirement. Include the following verbiage I'm the site plan demonstrating your neighbor has no objection to the location of the structure: "My name is _______ and I am the owner of the property located at________. I have reviewed the site plan and have no objection to the structure being located or constructed _____ feet from the property line as depicted in the site plan Signature: ________ Date:________" For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 11/29/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM08523 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Provide a single set of plans in a .PDF file. Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits SECTIONS - DETAILS: 1 Show a cross-section detail of the proposed exterior wall, R106.1.1. Show 3/8” structural or ½” non-structural wall sheathing of the proposed exterior wall, R106.1.1. 2 Provide a wall detail showing a 6” minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5. Also, show a pressure treated sill plate with ½” x 10” @ 4’ O.C. anchor bolts with 7” embedment into a 12” x 12” continuous foundation with #4 bear reinforcement. Show any weep screed with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. This may require a design with concrete stems. ELECTRICAL PLANS: 1. Show any electrical outlet location with circuit number. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |