Permit Number: T21CM08438
Parcel: 133363080

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM08438
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2021 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T21CM08438
SFR - new addition and carport enclosure (2ND Review)
9921 E Potomac Pl

TRANSMITTAL DATE: November 22, 2021

DUE DATE: November 24, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The site is located in the R-1 zone and the proposed use is single family residential, which is permitted in the R-1 zone, subject to use specific standard 4.9.7.B.5-.9 (Table 4.8-2).

01.COMMENT: Include the floor plan for the existing dwelling with dimensions on the plan set.

02.COMMENT: The family room qualifies towards the bedroom count - there are four (4) existing bedrooms with one (1) additional proposed bedroom addition. Per UDC, 4.9.7.B.7 - for any new single-family dwelling with five bedrooms, three parking spaces are required and all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in the vehicular use area in any front street perimeter yard. Demonstrate compliance with this standard.

03.COMMENT: An independent kitchen facility is not permitted. The accessory cooking facility is permitted to have an under the counter refrigerator, and a wet bar. No stove or full-size refrigerator is permitted (Table 6.3-2.A).

04.COMMENT: Provide the height of the wall, measured from grade to the highest point of the wall, to demonstrate compliance with the minimum required setbacks for your zone. The minimum required setback for your zone is the greater of 6' or 2/3 the height of the wall, measured from the exterior wall to the property line.


For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp