Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM08215
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/28/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM08215 5308 E 2nd St – R-1 Existing Detached Garage Expansion and Repair TRANSMITTAL: October 28, 2021 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). 1. Proposed side street perimeter yard setback from the proposed expansion to the street perimeter yard property line along Beverly Ave. is 8’-5”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 2. Based on a wall height less than 9’-0” the required perimeter yard setback from the proposed garage expansion to the south property line is 6’-0”, proposed setback is 1’-0”. This setback reduction can be dealt with in one of two ways, 1) Process within the required DDO process stated above for the side street perimeter yard setback or, 2) Secure a neighbor’s setback waiver. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the property owner of the house to the south. Provide the following text on the plot plan: My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ This setback waiver only applies to the south perimeter yard setback. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 10/28/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 11/10/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed |