Permit Number: T21CM08195
Parcel: 133090290

Review Status: Completed

Review Details: OTHER

Permit Number - T21CM08195
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/10/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide an engineer's stamped design of a non-prescriptive structure foundation. The pier depth is not shown.
11/12/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM08195
8045 E Mi Casita St – RX-1
Detached structure with Solar (1st Review)

TRANSMITTAL DATE:

This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3). See Use-Specific Standards 4.9.7.B.6, .8, & .9.

1. The minimum setback is twenty feet (20) facing each interior property line (Table 6.3-1.A). Proposed perimeter yard setback to the north property line is 13’-3” and to the east property line is 16’-5”. At a minimum a neighbor setback waive must be obtained. To secure this waive provide the following statement on the plot plan for the three (3) property owners at 8075 E Mi Casita St, 8050 & 8070 E Pima St. and have the owners sign and date the applicable statements:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________
If you are unable to secure the 3 required waivers a Design Development Option (DDO) will need to be processed to reduce the required perimeter yard setbacks. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.


2. The property dimensions shown on the plan are not correct, review the Mi Casita plat and provide the correct property dimensions.

3. Show the 7’-6” utility easement that runs along the north property line on the plot plan.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
11/22/2021 SBLOOD1 ENGINEERING REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
11/22/2021 VVERA1 OUT TO CUSTOMER Completed