Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM08113
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2021 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T21CM08113 208 N Palomas Av Master bathroom addition (1st Review) TRANSMITTAL DATE: October 14, 2021 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure; accessory structures less than 200 square feet gfa are exempt from this requirement (UDC Section 6.6.3.D). 1. There is a ramada on the site plan that was constructed without permits around 2019. Please provide permit documentation for this ramada. In addition, there appears to be a breezeway constructed without permits around 2018 connecting the existing residence and existing carport. Please provide permit documentation and show this on the site plan. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall (UDC Section 6.4.5.B and Figure 6.4.5-A). 2. The minimum setback is the greater of six feet, or two-third the height of the structure's wall facing the interior property line (Table 6.3-2.A). Based on a wall height of 10'-0" the required perimeter yard setback from the proposed master bathroom to the south property line is 6'-7"; proposed setback is 5'-6". A Design Development Option (DDO) will be required if the elevations remain as shown, and/or if proof of permitting of the existing porch cannot be found. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and must be submitted: https://www.tucsonaz.gov/pdsd-filedrop, using the submission type "Zoning Administration." If you have any questions about the DDO application or process, please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at (520)837-4951. |
| 10/14/2021 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
| 11/04/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM08113 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: Clarify if the porch roof is to be removed for providing the roof framing shown on sheet #3, R106.1.1. Update the “porch enclose” note or change the “new roof” framing on sheet #3. Show an existing or upgraded 1” line to the building. FRAMING PLAN: Provide a roof framing plan showing a ridge beam or add ceiling joist sixes for a ridge board with required joist, R802.3. PLUMBING PLANS: Provide any alterations with details showing piping with compliant materials and sizes. Remove the optional gray water notes or provide a complete compliant system as all fixtures must drain to the county sewer if the gray water becomes inoperable. ELECTRICAL PLANS: Notate a dedicated 20 AMP circuit for the proposed bathroom. The shower light switch must be out of reach from the shower. OUTDOOR LIGHTING CODE Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |