Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM08028
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/25/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM08027 & T21CM08028 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied T21CM08027 - Service Building 1. The fire extinguishers under the life safety systems data box is missing the applicable code information. Provide the applicable code information that is missing. 2. The occupant load factor used in the occupant load calculation for the service area is incorrect. This most resembles a 200 gross use load factor. Provide the correct occupant load factor and recalculate the occupant load in accordance with Table 1004.5. 3. The occupant load on the cover page doesn't match the occupant load on Sheet G1.3. Additionally the break room and training room is calculated inappropriately. Please recalculate all areas and correlate all applicable requirements. 4. Ensure a clear path is maintained through the tool area for egress. T21CM08028 1. No drawings submitted for this permit #. Submit construction drawings for the cosmetic building. MECHANICAL REVIEW COMMENTS: Approval Pending 1. Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Denied E1.0 SERVICE BUILDING LIGHTING PLAN: Need a comcheck for interior lighting renovation. Cannot locate Notes 7 and 11. E1.1 SERVICE BUILDING POWER PLAN: Could not locate Notes 1, 12, and 14. PLUMBING REVIEW COMMENTS: Denied 1), Lavatory faucets need to be automatic type per -Tucson ICC 2018 Plumbing code amendments 412.11 & 419.6 Update P3 & P7 fixture information on plan page P4.0 2). Add urinal side wall/partition to center clearance measurements to plan page A2.2 -IPC 405.3.1 3). Ice maker/coffee boxes detail #6 on plan page P4.0 needs to include proper backflow devices. -IPC 608.17.1.2 4). Add the floor drain/trap primer information to plan page P4.0 plumbing fixture schedule. -IPC A106.3.1 5). Add a floor drain trap primer detail to plan page P4.0. -IPC A106.3.1 |
| 11/02/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 11/02/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM08027 & T21CM08028 4755 N Oracle Rd – C-3 TI – Auto Sales TRANSMITTAL: November 2, 2021 This site is located in the C-3 zone (UDC 4.7.22). Auto Sales is an allowed use in the zone, UDC Table 4.8-4 subject to Use Specific Standards 4.9.9.G.1& .2. 1. It does not appear that plans were submitted for “COSMETIC” TI. Either submit the plans or withdraw the permit. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 11/16/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Cosmetic plans for the Carwash FQC center are missing from the plan set for T21CM08027 Questions: Jennifer Peel-Davis 520-837-7033 Jennifer.Peel-Davis@Tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/17/2021 | NGARCIA3 | OUT TO CUSTOMER | Completed |