| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2021 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | FROM: Samuel Rogers PDSD Zoning Review Section PROJECT: T21CM07949 New Garage (1st Review) 3220 S AMES PL TRANSMITTAL DATE: 10/14/2021 DUE DATE: 10/21/2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: The provided site plan is missing some required information (setbacks, lot coverage calculation, adjacent zoning, north arrow, etc.) For full site/plot plan requirements see 02. COMMENT: Provide an elevation drawing showing the height of the proposed structure measured from design grade to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof. (You can use the image provided on the 1st page of plans as your elevation drawing and add/draw the heights) 03. COMMENT: Detached accessory structures may not exceed 12' in height. 04. COMMENT: The setback requirement is based on the height of the adjacent wall (6' or 2/3 the height of the wall), provide the wall height so required setbacks can be determined. 05. COMMENT: The total gross floor area (GFA) of the accessory structure may not exceed 25% the GFA of the principle structure. If you have any questions about this transmittal, Contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 10/14/2021 | SROGERS2 | ENGINEERING | REVIEW | Passed | |
| 11/01/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide the manufacturer’s calculations, data and sealed Arizona engineered plans for the pre-designed assembly, R106.1. Show the electrical service to the property. An overhead line requires appropriate clearance above buildings, E3604.2.1. |