Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM07491
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/25/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Sheet A312 shows a fixed ladder but also states that it will have a security gate? Is that a gate in the stairwell and or a cage around the ladder? New Note on A311 shall also state building ERRC test to only be performed by PCWIN. Provide copies of the approved appeals with your next submittal. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
01/26/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
02/08/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM07491 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Denied 1. Provide ventilation calculation tables (IMC 2018, 403.3.1.1.1) See sheet M100 with ventilation calculations. Not Complied You did not provide sheet M100 in your submittal 2. Bathroom exhaust ducts that penetrate more than 2 stories shall be encased in a shaft. (IMC 2018, 607)a. Upper-level exhaust fans conform to 2018 IBC exception requirements 1 through 5 of section 717.6.1. The 26 gauge exhaust fan is wall mounted and the duct runs continuous in the wall from the guest unit to the exterior of the building. Not Complied you are running duct 4stories the exception is for running the duct inside the cavity of the wall directly to the outdoors for no more than 3 stories 3. Complied 4. Dryer ducts penetrating fire rated ceiling shall be protected in an approved manner. (IMC 2018, 607.2) Dryer ducts inside joist space that penetrated fire rated floor/ceiling assembly are protected with continuous fire duct wrap from penetration to termination, see keynote #13 on sheet M401 Complied 5. Provide Ceiling radiation damper where duct penetrates fire rated floor/ceiling assembly. (IMC 2018, 607.6) All grille penetrations through rated ceiling assemblies are protected with radiation dampers (see CRD tags on sheet M401) Complied 6. Provide a level platform to appliance on roof with a slope of 3/12 or greater in an approved manner (relief hood, roof hatch) (IMC2018,306.5.1) Complied ELECTRICAL REVIEW COMMENTS Denied E602 – Lighting Fixture Schedule: a. Need a lighting Comcheck, both interior and exterior. EOR Response: Interior ComCheck has been included, and Exterior calculations have bben added to the documents. Reviewer: Could not locate interior lighting Comcheck report. PLUMBING REVIEW COMMENTS: Denied SECOND PLUMBING REVIEW: 1 THRU 4 OK 5). SAME-. Add fixture spacing measurements to detail #4 on A500 and or P401. -IPC 404.2, 405.3.1 6 THRU 13 OK 14). NOW THAT LINT INTERCEPTOR INFO HAS BEEN ADDED TO P401, A LINT INTERCEPTOR DETAIL NEEDS TO BE ADDED TO THE PLUMBING PLANS & NEEDS TO CORRELATE WITH DETAIL #3 ON P501. -IPC A106.3.1 15). OK 16). SAME-Add beverage equipment backflows to P602. - IPC 608.17.1.1 thru 608.17.1.2 ( WATER CONNECTION FOR ICE MACHINES SHOWN ON P402) 17 THRU 21 OK |
02/08/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
02/18/2022 | LSHAMIS1 | ZONING | REVIEW | Approved |