Permit Number: T21CM07342
Parcel: 136202670

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM07342
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/16/2021 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T21CM07342
SFR addition - 2-bedroom addition (1st Review)
2611 S Panther Pl

TRANSMITTAL DATE: September 16, 2021

DUE DATE: September 28, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The use is single-family residential (SFR) which is a permitted use in the O-3 zone (Table 4.8-3).

01. COMMENT: Provide a residential plot plan that meets the requirements found at https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf
02. COMMENT: Include the lot coverage calculation (UDC, 6.4.3)
03. COMMENT: Include the zones of the adjacent property
04. COMMENT: Provide the height of the northern elevation measured from design grade to the highest point of the wall (UDC, 6.4.5.B).
05. COMMENT: indicate the maximum structure height (UDC, 6.4.4.A).
06. COMMENT: Include adjacent right of ways and demonstrate setback compliance for the northern property line. Golf Links Road is a Major Street and Route, designating the subject property as a developing area in relation to setback requirements (UDC, 6.4.5.C.2). The average daily traffic for Golf Links is 1,000 or greater, resulting in a minimum setback requirement of 21' or the height of the adjacent wall, the greater applies, measured from the wall to the back of the existing or future curb location (Table 6.4.5.C-1).

For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
10/07/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM07342

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Place the reference on the plans.

Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits

SITE PLAN:

Provide a site plan showing all buildings, R106.1.1. Show the location of utility lines to the building.

SECTIONS - DETAILS:

New exterior and bearing walls require compliant attachment to a 12” wide x 12” deep reinforced foundation. Also, show a minimum 6" spacing above exterior grade or 2” above exterior concrete surfaces. Update detail #1 and 2 on sheet 3.

An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF.

MECHANICAL PLANS:

Provide equipment details showing code compliant components, locations and sizes. Provide heating facilities in all habitable rooms, R303.9.

ELECTRICAL PLANS:

Show a smoke alarm in each bedroom and outside in the immediate vicinity, R314.3.2.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
10/20/2021 SBLOOD1 ENGINEERING REVIEW Passed