Review Date Reviewer's Name Type of Review Description Status Comments
09/10/2021 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T21CM07156
SFR bedroom and porch addition (1st Review)
2909 E Copper St

TRANSMITTAL DATE: September 10, 2021

DUE DATE: September 20, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The use is single family residential (SFR) which is permitted in the R-1 zone, subject to use specific standards 4.9.7.B.1 - .9 and .11 (table 4.8-2).

01. COMMENT: It is unclear if the addition is meeting the minimum required setbacks to the western property line. Setbacks are variable for the R-1 zone - the minimum setback requirement is 6' or two-thirds (2/3) the height of the adjacent wall (H), the greater applies, measured to the property line (UDC, Table 6.3-2.A). Provide the height of the west elevation measured from grade to the highest point of the wall to determine the setback requirement to the property line (UDC, 6.4.5).
02. COMMENT: Include the property owner's name on the site plan.
03. COMMENT: Correct the dimensions of the parcel - the subdivision plat states the width of the parcel is 67.5' (M&P, book 8, page 30)

For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/20/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp.
Instructions:
1. Is this for a new or existing activity application? - Please select New Application.

2. Submission Type - Select Floodplain Use Permit.

3. Project Name - Enter a name for your project.

4. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided.

5. Type of Permit - Select Commercial or Residential (Residential is for work on single family residences and duplexes.)

6. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account.

7. Complete the Contractor, Owner and Architect/Engineer sections as applicable.

8. Supporting Documentation Upload - Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful.

9. Sign the application and submit.