Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM07030
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/08/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM06953/APT BLDG & T21CM07030/DEMO & CLUBHOUSE GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. The allowable tabular sq. ft. provided for building 1 on the area increase calculations is incorrect. The max tabular allowable sq. ft. for an A-2 occupancy of type V-B construction and protected by a NFPA 13 system is 24,000 sq. ft. according to Table 506.2. Provide clarification and provide updated area increase calculations. 2. It is assumed that a 13R sprinkler system is being used to protect the apartment building and a NFPA 13 sprinkler system is protecting the new clubhouse. The notes are vague is what systems are protecting what spaces. Please clearly indicate what sprinkler systems types are protecting what spaces. 3. During the demolition phase it will be important to maintain all the fire lanes and fire access. Please coordinate with the Fire Marshal. 4. There are no egress plans provided. Provide thorough egress plans for both the apartment building and the clubhouse. 5. There are no occupant loads provided. Provide occupant load calculations for both the apartment and clubhouse. MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Approved |
09/13/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM06953 & T21CM07030 3332 N Los Altos Ave Multifamily & Clubhouse (1st Review) TRANSMITTAL: September 13, 2021 This site is located in the R-3 zone (UDC 4.7.12). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6. 1. The building plans have been reviewed for compliance with Development Package (DP) DP21-0212, and although it appears that the building plans match the DP, until the DP is approved Zoning cannot approved the building plans. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
09/13/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
09/16/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
09/24/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
10/18/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: 1. Is this for a new or existing activity application? - Please select New Application. 2. Submission Type - Select Floodplain Use Permit. 3. Project Name - Enter a name for your project. 4. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. 5. Type of Permit - Select Commercial or Residential (Residential is for work on single family residences and duplexes.) 6. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account. 7. Complete the Contractor, Owner and Architect/Engineer sections as applicable. 8. Supporting Documentation Upload - Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful. 9. Sign the application and submit. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
10/19/2021 | VVERA1 | OUT TO CUSTOMER | Completed |