Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM06825
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/30/2021 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | CDRC Transmittal FROM: Loran Shamis PDSD Zoning Review Section PROJECT: T21CM6825 SFR guest suite addition (1st Review) 143 W Roger Rd TRANSMITTAL DATE: August 30, 2021 DUE DATE: September 7, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The proposed use is single family residential (SFR) which is permitted in the R-2 zone (UDC 11.3.7.A.4), subject to use-specific standards 4.9.7.B.6, .9, and .10 (Table 4.8-2). 01. COMMENT: Provide the information that is required in the residential plot plan found here - https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf 02. COMMENT: Provide the dimensions and square footage of the buildings, storage, and vehicular use area to determine the lot coverage. The lot coverage calculation is the percent of area of all buildings and storage areas measured within the outside edges of the exterior walls and the vehicular use area, measured within the outside edges of any area allocated to vehicular use of the entire lot area (UDC 6.4.3) 03. COMMENT: Correct the legal description to "AMPHITHEATER ACRES N 125' OF S 250' IF W 106' OF LOT 8" For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 09/16/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 09/16/2021 | AWARNER1 | NPPO | REVIEW | Passed | |
| 09/21/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM06825 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Indicate the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Show the utility lines requiring upgrade or replacement. SECTIONS - DETAILS: 1. Show an individual accessible water supply shut off at each building entrance, P2903.9.1. ELECTRICAL PLANS: 1. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |