Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM06743
Parcel: 116020770

Address:
1852 N ATWOOD AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM06743
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Revise Detail #4. Show an existing foundation or toe down. Connect the 8" CMU to the foundation with 1/2" rebar @ 48" OC. Change the anchor bolt size to 1/2" x 10". Consider leveling the Living Room floor.
11/04/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM06743
SFR addition - enclose garage and add carport (3rd Review)
1852 N Atwood Av

TRANSMITTAL DATE: November 4, 2021

DUE DATE: November 10, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

This comment was not addressed.
1. COMMENT: As this site would be considered Established Area for determining street perimeter yard setbacks, see definition of Established Area UDC Article 11.4.6, per UDC Article 6.4.5.C.1.a within established areas, the minimum required front street perimeter yard is 20 feet or one and one-half the height of the proposed wall (H), greater of the two, measured from the street property line. Based on a height of 9'6" the required street perimeter yard setback to the property line along Atwood Av is 20' proposed is 3'. A Design Development Option shall be submitted and approved to reduce the front street perimeter yard setbacks. Until the DDO is approved and the 14 day appeal period has expired Zoning cannot approve this plan. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov