Permit Number: T21CM06734
Parcel: 113071770

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM06734
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Show compliance with R310 providing egress from a bedroom with minimum net clear opening area of 5.7 SQ FT (5 SQ FT 1st floor). Also, show the minimum net clear opening dimension of 24” height and 20” width, and maximum sill height of 44”.

Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets, E3703.2 and E3901.3.
09/21/2021 STEVE SHIELDS ZONING REVIEW Approved
10/19/2021 SBLOOD1 ENGINEERING REVIEW Passed