Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM06635
Parcel: 138070020

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM06635
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/18/2021 PCAMARE1 ENGINEERING REVIEW Passed
08/26/2021 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T21CM06635
Single family residential, storage addition (1st Review)
810 W Santa Rosa St

TRANSMITTAL DATE: August 26, 2021

DUE DATE: September 1, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The proposed use is single family residential which is permitted in the R-1 zone, use specific standards 4.9.7.B.1-.9 and .11 are applicable (UDC, Table 4.8-2).

01. COMMENT: It appears the accessory structure is not meeting the minimum setback requirements to the west. The setback requirements for this site is 6' or 2/3 the highest point of the adjacent structure wall, the greater distance applies, measured from the exterior adjacent wall to the property boundary. Provide the dimensions of the highest point of each wall measured from design grade for the north and the west walls of the accessory structure to determine the setback requirements (UCD, Section 6.4.5).

02. COMMENT: The size of the parcel and the lot coverage calculation is incorrect based on the subdivision plat dimensions of the parcel which are expressed as 71' by 120' resulting in 8,520 square feet of lot area.

For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/09/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM06635

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

Update the electrical panel keynote.

SECTIONS - DETAILS:

1 Provide a complete roof framing plan with the addition ridge beam sized with appropriate load carrying capacity. Show roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3.

ELECTRICAL PLANS:

1. A feeder and sub panel is required for serving the detached building with more than two circuits, NEC 225.30 and E3403, E3607.
2. Branch Circuit: Show circuit #25 receptacles with GFCI protection, E3902.2.

If you have any questions, please contact:
Ken Van Karsen
(520) 791-5550
City of Tucson Residential Plan Review