Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM06621
1745 E 2nd St – R-3
At Metal Fence to Site wall (1st Review)

TRANSMITTAL DATE: September 2, 2021

This site is located in the R-3 zone (UDC 4.7.12). A Group Dwelling is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standard 4.9.7.B.6.

1. Per UDC Article 6.3.3.D.2 a group dwelling is considered a non-residential use there for a Development Package (DP) that meets the minimum requirements of the Checklist for Minor Changes to Commercial/Industrial Site must be submitted and approved for this wall/fence. The checklist can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf. The DP is a separate submittal from the building plan and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using the submission type “Site Review”.

2. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .)
1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron;
2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall;
3. A greater height is required through the rezoning process or the special exception land use process; or,
4. A greater height is required by a specific UDC standard.

3. Based on the drawing provided the proposed metal fence does not meet any of the exceptions listed above and will require a Board of Adjustment for Variance for the 10’-0” propose height. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdfThe Board of Adjustment is a separate submittal from the building plans and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the submission type “Zoning Administration”. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966
09/02/2021 SSHIELD1 ENGINEERING REVIEW Passed
09/13/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. General: This project is considered a commercial building classification, therefore the drawings require a registered architect or engineer to seal, sign, and date all documents.
2. General: Please provide a site plan indicating the location of the new fencing. In addition, indicate the type of fencing, the height of the new fencing, and the length of the new fencing on the site plan.
3. General: Please provide drawings, details, specifications, etc. of the new fencing as required.
4. General: Structural calculations by a registered design professional are required for the new fencing and connection of that fencing to the existing fence.
5. General: Please provide written responses to all review comments.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/13/2021 VVERA1 OUT TO CUSTOMER Completed