The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T21CM06426
Parcel: 125075660

Address:
2121 E 8TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM06426
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/01/2021 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC Transmittal

FROM: PDSD Zoning Review

PROJECT: T21CM06426
SFR carport addition (3rd Review)
2121 E 8th St

TRANSMITTAL DATE: December 1, 2021

DUE DATE: December 7, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The use is single family residential (SFR) which is permitted in the R-1 zone, subject to use specific standards 4.9.7.B.1 - .9 and .11 (Table 4.8-2).

1. This comment was not addressed correctly. In you comment response letter you state that “The previous plan set I submitted was incorrect. The distance from property line to curb is 10 feet (NOT 20 feet)” but based on COT Paving plan I-420 the distance from face of curb to the property line is 20’-0”. Either use the 20’-0” distance or provide a survey produced by a registered surveyor with the next submittal that verifies your 10’ distance. COMMENT: It is unclear whether the carport addition is meeting the front yard setback requirements. The site is in an established area for the purpose of determining front yard setback requirements - within established areas, the minimum required front yard setback is 20' measured from the property line (UDC, 6.4.5.C.1). Based on the dimensions provided, the proposed carport's front yard setback is 18'. Per UDC standard 6.4.5.D.2.a. within established areas, a roof overhang may extend two feet into the required street yard. Demonstrate compliance with these standards.

2. The plans are not consistent. The provided plot plan shows the carport as 8 ft in depth but the framing plan shows 12’.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
12/06/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM06426
PLAN REVIEW COMMENTS

SITE PLAN:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

Show a reference to the engineered framing plans for carport type of construction.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
520 837-4912
City of Tucson Residential Plan Review