Review Date Reviewer's Name Type of Review Description Status Comments
08/10/2021 SBLOOD1 ENGINEERING REVIEW Passed
08/18/2021 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T21CM06351
Single family residential - porch addition (1st Review)
6010 S Southland Blvd

TRANSMITTAL DATE: August 18, 2021

DUE DATE: August 23, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The proposed use is single family residential which is a permitted use in the R-2 zone, with use-specific standards 4.9.7.B.6, .9, and .10 are applicable (UDC, Table 4.8-2)

01. COMMENT: The proposed porch addition is not meeting the minimum setback requirements for the R-2 zone. The minimum setback requirements are 6' or 2/3 of the highest point of the adjacent wall, the greater applies, measured from the property line to the nearest post of the proposed porch.
02. COMMENT: To reduce the permitted minimum required setback there are two options, 1.) a neighbor waiver signoff or 2.) a Design Development Option (DDO) may be applicable.
For the neighbor waiver signoff, include the following language on the site plan with the signature of 5960 S Southland Blvd:
"My name is ___________ and I am the owner of the property located at _____________. I have reviewed the site plan and I have no objection to the structure being located or constructed ________ feet from the property line as depicted on the site plan.
Signature: ___________
Date: _______________"

The other option to reduce setbacks is the DDO, which is a separate application and can be accessed here - https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf

03. COMMENT: It appears there are some structures towards the western portion of the property that must be included in your site plan - include all existing improvements on the site.

For questions regarding Zoning comments, please contact me at: Loran.Shamis@tucsonaz.gov
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/01/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM06351
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration

GENERAL COMMENTS:

1. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the structure’s assembly and alterations for achieving code compliance.

SITE PLAN:

1. Indicate the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Show the utility lines extending into the construction area.

FRAMING PLAN:

1. Structures with a fire separation distance less than 3-foot to the property line require not less than one-hour fire-resistive construction. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3.
2. Provide an engineer’s calculation, design and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. Railroad beams are not included in the 2018 IRC.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review