Permit Number: T21CM06281
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM06281
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/01/2021 GPENNIN1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
FROM: PDSD Zoning Review
PROJECT: T21CM06281
6716 S Van Buren Ave - R-1
Attached Porch & Detached Ramada (2nd Review)

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.
1. Per Unified Development Code (UDC) TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 Zone, Residential Use to Residential Zone, based on a wall height less than 9'-0" the required perimeter setback from the ramada to the west and south property line is 6'-0" or 2/3 the height of the structure, whichever is greater. The proposed setback is 5'-6" to the west and 5'0" to the south. At a minimum a neighbor setback waiver is required from all adjacent property owners along the west and south lot lines (three properties in this case), see UDC Article 6.6.2.D. Additionally, ensure the requested setback on the waivers matches what is shown on the site plan.
The statement below needs to be actually on site plan itself, not as separate attachment.
"My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan."
Signature: _____________________________
Date: _________________________________

If you are unable to secure the neighbor setback waiver a Design Development Option (DDO) will be required. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type "Zoning Administration". If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov
10/11/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed