Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM06218
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/11/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide a complete set a structural calculations for the new generator room. BUILDING REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Denied E1.2 ELECTRICAL PLANS - 17TH FLOOR & ELEVATOR EQUIP RM: No electrical issues, Elevator conductor wire is oversized and may cause constructability issues. E2.4 SYSTEMS PLANS - 17TH FLOOR: No electrical issues, Notes 1&2 not used? E3.0 ONE LINE DIAGRAM AND CALCULATIONS: 1000 amp CB in MSB is undersized in relation to 1600 amp ATS and 600 KW generator. Panel load is below 1000 amps so this is not a code issue. EM2 is 22KAIC rated on schedule and Fault current analysis calls for 42 KA rating. The short circuit calculation shows 23,485 Amps. Resolve. Where is EMM panel? Comment only: Transformer sizes seem non-standard. E3.1 PANEL SCHEDULES: Suggest to rephase ‘(Renamed EM4)’ to ‘(Formerly EM4)’ Confirm Existing EMP panel has several 1 Pole 60 amp Circuit breakers. MECHANICAL REVIEW COMMENTS: Approved Pending 1. Approved/subject to field approval PLUMBING REVIEW COMMENTS: N/A |
| 08/19/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/23/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM06218 1501 N Oracle Rd Elevator Modification and Site Work (1st Review) TRANSMITTAL DATE: August 23, 2021 This site is located in the OCR-1 zone (UDC 4.7.26). 1. Per UDC Article 3.3.3.G.2.c A site plan is required for the following types of development: c. Existing development undergoing a change of use , building or structure additions, and/or a reconfiguration of an area outside a building. That said as you are proposing a reconfiguration of an area outside a building a Development Package (DP)meeting the minimum requirements of the checklist for Minor Changes to Commercial/Industrial Sites found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf, must be submitted and approved showing how the pedestrian circulation will be provided. Only minor changes such as upgrades to accessible vehicle parking and accessible access are allowed on tenant improvement plans. If you elect to eliminate a required pedestrian circulation component A Board of Adjustment for Variance will be required. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966 |
| 08/30/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 08/30/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | See Zoning comment about need for a DP |
| 10/07/2021 | DBENOIT1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Reqs Change |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/07/2021 | DBENOIT1 | APPROVAL SHELF | Completed |
| 10/07/2021 | DBENOIT1 | OUT TO CUSTOMER | Completed |
| 10/07/2021 | DBENOIT1 | REJECT SHELF | Completed |