Permit Number: T21CM05980
Parcel: 140420100

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T21CM05980
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2021 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM05980

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

STRUCTURAL REVIEW COMMENTS:
Approved

BUILDING REVIEW COMMENTS:
Denied
1. Sheet A1.0 – General Building Summary shows occupancy group(s) of only Business (B), however new warehouse/shop space is indicated using storage occupancy load factor. Isn’t this mix occupancy between B and S2? Clarify.
2. Sheet A2.0 – Show the adjacent existing occupancy between the existing demising wall between grid D/E. Is it B or S2 occupancy for existing sign company?
3. A2.0 – The existing wall at grid F wall type B “EXISTING DEMISING WALL” was mentioned by Mr. Jose (Architect) to be existing 1 hour wall. Please update wall type B and D to show continuous protection. Provide UL assembly and any penetration details as required.
4. A5.0 – Doors 139A and 145A are shown as NR/non rated doors on existing 1 hour wall. Provide fire rating per 2018 IBC table 716.5.
5. A2.0 – Is there any hazardous materials per 2018 IBC 307 stored in Storage 152? Y/N.

MECHANICAL REVIEW COMMENTS:
Approved

ELECTRICAL REVIEW COMMENTS
Approved

PLUMBING REVIEW COMMENTS:
Approved
08/12/2021 ROBERT SHERRY WATER REVIEW Completed
08/16/2021 SSHIELD1 ENGINEERING REVIEW Passed
08/16/2021 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM05980
2850 E Valencia Rd
TI – Construction Services (1st Review)

TRANSMITTAL DATE: August 16, 2021

This site is located in the PI zone (UDC 4.7.28). Construction Service is not a permitted use in this zone (Table 4.8-5).

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966
08/16/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
08/25/2021 JPEELDA1 FIRE REVIEW Approved