07/28/2021 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM05753

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

STRUCTURAL REVIEW COMMENTS:
Approved

BUILDING REVIEW COMMENTS:
Denied
1. No egress plan provided. Provide a thorough egress plan showing travel distances and all other requirements.
2. Door 101-1X projects into the exit stairwell blocking the means of egress. Provide a door that complies with Section 1005.7.1
3. Door 102-1X swings the incorrect direction. This occupancy will have more than 50 occupants traveling through the space. Provide a door swing that complies with Section 1010.1.2.1
4. Provide the width of corridor 100. Ensure door swings comply with 1010.1.2.1.
5. Provide the width of corridor 109 and corridor 110. Ensure compliance with Section 1020.2
6. Entry 100 is a corridor. Door 103-1X and door 102-1X are required to have a rating of 20 min and a sidelight rating of 20 min. per Table 716.1(2)
7. Entry 100 is a corridor. The window in Entry 100 is required to have a rating of 20 min per Table 716.1(3)

MECHANICAL REVIEW COMMENTS:
Denied
1. There is no air circulation provided to the lower level corridor. Provide narrative as to why no air circulation is provided to this area or provide necessary circulation.
2. There are mechanical penetrations into the stairway. Provide the damper details.
3. The bathroom exhaust fans are required to comply with Table 403.3.2.3. Are they continuous or intermittent?
4. Provide the complete outdoor calculations for all spaces and the dwelling units that are compliance with Section 403.3.2

ELECTRICAL REVIEW COMMENTS
Approved

PLUMBING REVIEW COMMENTS:
Approved
07/29/2021 JVINCEN1 FIRE REVIEW Approved
07/29/2021 ROBERT SHERRY WATER REVIEW Completed
08/09/2021 STEVE SHIELDS ZONING REVIEW Approved
08/09/2021 SSHIELD1 ENGINEERING REVIEW Passed
08/09/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
08/09/2021 VVERA1 OUT TO CUSTOMER Completed