Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T21CM05625
Parcel: Unknown

Address:
1240 S 10TH AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM05625
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM05625
1240 S 10th Ave
New SFR (2nd Review)

TRANSMITTAL DATE: September 9, 2021

This site is located in the R-3 zone (UDC 4.7.12). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6.

1. This comment was not addressed. Until land split S21-021 has been approved the SFR cannot be approved.

2. As you are now proposing an alley exit provide documentation from the City Engineer, Fred Felxi with the Department of Transportation & Mobility, that the requirements of UDC Article 7.4.6.K.2, An alley, when used for access, must be a minimum of 20 feet wide, free of obstructions, and surfaced with a dust control method that is acceptable to the TDOT City Engineer, are met. As 10th Ave is a collector listed on the COT MS&R plan per UDC Article 7.4.6.K.A.4 an MS&R may not be used for maneuvering into a parking space on to a residential site. If the MS&R will provide vehicle access to the site all maneuvering must be on site. Either show that no access will be provided to 10th or show that all maneuvering will be on site.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
09/16/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed