Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/01/2021 STEVE SHIELDS ZONING REVIEW Approved
09/02/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Show compliance with R310 providing egress from a bedroom with minimum net clear opening area of 5.7 SQ FT (5 SQ FT 1st floor). Also, show the minimum net clear opening dimension of 24” height and 20” width, and maximum sill height of 44”.

Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets, E3703.2 and E3901.3.