Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM05526
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/06/2021 | DBENOIT1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | PLEASE PROVIDE INDIVIDUAL BULDING NUMBER PRIOR TO PERMIT ISSUANCE. addressing@pima.gov, 724-9512 |
| 07/13/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 07/22/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/26/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM05449/5523-5539 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Non-load bearing walls require a deflection track or details to allow for the relative lateral deflection of the structural members. 2. Refer Drawing S1.2, Deferred Submittals Section references IBC 2012. Provide accurate information regarding Current Code International Building Code 2018. The information provided is incorrect since State has adopted latest Codes. Make revisions as needed. BUILDING REVIEW COMMENTS: Denied TYPE A 1. Occupant notification system is required per Section 907.2.9.1 Exception #2 and all applicable requirements of 907.5. 2. No egress plan provided for the Type A building. Provide a full egress plan. 3. No section detail provided for the fire wall. Provide a UL 2 hour listed assembly for the fire wall. The fire wall is required to have a 2 hour fire rated resistance rating per Table 706.4. TYPE B 1. Occupant notification system is required per Section 907.2.9.1 Exception #2 and all applicable requirements of 907.5. 2. No egress plan provided for the Type B building. Provide a full egress plan. 3. No section detail provided for the fire wall. Provide a UL 2 hour listed assembly for the fire wall. The fire wall is required to have a 2 hour fire rated resistance rating per Table 706.4. REC BUILDING 1. No egress plan provided for the rec/office building. Provide a full egress plan. MAINTENANCE BUILDING 1. No construction type provided for the maintenance building. Provide construction type. 2. No occupancy classification provided for the maintenance building. Provide the occupancy classification. 3. No occupancy load provided for the maintenance building. Provide a calculated occupant load. 4. No egress plan provided for the maintenance building. Provide a full egress plan. MECHANICAL REVIEW COMMENTS: Denied 1. Provide ceiling radiation dampers on all bathrooms, kitchens on all apartments on this project (IMC2018,607.6.2) 2. Dryer exhaust shall not penetrate fore rated floor/ wall ceiling assembly unless its protected by a shaft for all apartment units (IMC2018,504.2) 3. Provide conditioned air to exercise room (IMC2018,403.1) 4. Please correct show the Vbz calculation then the Voz calculation (IMC2018,403.1.1,403.3.1.1.1.2,403.3.1.1.1.3) 5. Pool is not under this review per code summary on page 1 ELECTRICAL REVIEW COMMENTS Denied E1.0: Architectural comment: Where are units 2, 4, 7, & 8? Seem to have duplicates of 1, 3, 5, & 6. Confirm with Architect. E1.1: Architectural comment: Are the units properly labeled? Confirm with Architect. E5.0: No Electrical issues. May want to consider upsizing HP panels to support future EV chargers. PLUMBING REVIEW COMMENTS: Approved |
| 07/30/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM05449, T21CM05523, T21CM05524, T21CM05525, T21CM05526, T21CM05527, T21CM05528, T21CM05529, T21CM05530, T21CM05531, T21CM05532, T21CM05533, T21CM05534, T21CM05535, T21CM05536, T21CM05537, T21CM05538 & T21CM05539 2945 N Bear Canyon Rd – R-3 Multi-Family TRANSMITTAL: July 30, 2021 This site is located in the R-3 zone (UDC Article 4.7.12). A multi-family is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6. 1. Until development package DP21-0174 has been approved Zoning cannot approve the building plans. 2. There appears that there is a discrepancy between the DP and the building plans. DP shows Building Type “B” to have 4 one-bedroom units and 12 two-bedroom units, building plans show 16 two-bedroom units. This will affect the number of required vehicle parking spaces. 3. The development package sheets provided in the building plan set either need to be the stamped approved plans, marked for reference only or removed from the building plan set. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 07/30/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 08/06/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | The DP needs to be approved before the building plans can be approved. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/06/2021 | VVERA1 | OUT TO CUSTOMER | Completed |